Diagnostics and calibration

Diagnostics and calibration are the robot's body-awareness mechanisms. Diagnostics asks whether the robot is healthy enough to operate; calibration measures how the physical robot differs from its ideal model.

This section complements the user-facing Getting Started guide. That guide explains what to do; this page explains what the firmware is trying to establish internally.


Diagnostics before normal operation

The firmware can enter a dedicated diagnostic path during boot or from the user interface. This is useful when startup should not immediately enable normal locomotion.

A diagnostic sequence can verify:

  • whether required buses and peripherals initialize;
  • whether the selected screen and IMU respond;
  • whether motor feedback is available;
  • whether sensors produce plausible values;
  • whether the configuration matches the detected robot revision;
  • whether the body can move through a safe test sequence.
Generating schema ...
flowchart TD
    Boot[Boot or diagnostic request]
    Config[Load configuration]
    Hardware[Check buses and devices]
    Feedback[Check motor and sensor feedback]
    Decision{Checks passed?}
    Normal[Allow normal operation]
    Error[Show error and keep robot safe]

    Boot --> Config --> Hardware --> Feedback --> Decision
    Decision -->|yes| Normal
    Decision -->|no| Error

Diagnostics should fail visibly. A missing device must not be represented as a healthy zero value, because that could allow later code to command a body whose state is unknown.

Calibration versus diagnosis

These two operations are related but different:

OperationQuestion
DiagnosisIs the component responding and is the state plausible?
CalibrationWhat correction or physical parameter is needed for accurate control?

Calibration is therefore not a substitute for checking hardware health. A disconnected motor cannot be calibrated successfully, and an IMU with invalid readings should not be used to compute a correction.

Locomotion calibration

The locomotion calibration tools measure properties needed by the joint and motor control layers. The current firmware includes calibration paths for:

  • feedback inversion;
  • feedback deadband size;
  • feedback latency;
  • physical joint bounds.

These measurements help the controller relate a command to the actual motor response. The resulting values can then be used by the joint and motor-controller code instead of relying only on nominal hardware assumptions.

The calibration flow should keep the robot in a controlled posture and apply only the movement required for the current measurement:

Generating schema ...
flowchart LR
    Prepare[Safe posture and checks]
    Measure[Apply controlled test]
    Observe[Read motor feedback]
    Calculate[Calculate correction]
    Store[Store calibration data]
    Reboot[Reload active configuration]

    Prepare --> Measure --> Observe --> Calculate --> Store --> Reboot

Calibration can affect physical movement. Keep the robot supported as recommended by the user-facing procedure and stop the process if a joint behaves unexpectedly.

IMU and sensor calibration

The IMU layer corrects gyro bias and combines gyroscope and accelerometer information to estimate orientation. A stable initial posture is important because the estimator needs a reliable reference before stabilization can be trusted.

The diagnostics system should distinguish between:

  • a sensor that is present but needs calibration;
  • a sensor that returns implausible values;
  • a sensor that cannot be reached at all.

Those cases require different user actions. Re-running calibration will not fix an incorrect I2C address, wiring problem, or wrong runtime sensor type.

Persistent calibration data

Calibration values are configuration data rather than firmware code. They must be stored and loaded in a controlled way so that a firmware update does not accidentally erase the physical measurements needed by the robot.

The runtime hardware configuration is stored in /userdata/settings.json, with a backup at /userdata/settings.json.bak. Calibration data should follow the same principle of explicit persistence and validation. If a value is missing or invalid, the firmware should use a known default or block the affected operation rather than silently treating an unknown measurement as zero.

See Hardware abstraction and Memory, partitions, and updates for the configuration and storage layers.

Failure recovery

When a diagnostic check fails, the safest response depends on the component:

FailureAppropriate direction
Display unavailablePreserve logs and expose the error through LED/network where possible
IMU unavailable or invalidPrevent stabilization-dependent movement
Motor feedback invalidDo not enable the affected joint normally
Network unavailableKeep local controls and diagnostics available
Invalid configurationRestore defaults or request correction and reboot

The exact recovery path is subsystem-specific, but the principle is common: report the failure, reduce the robot's capabilities, and avoid continuing with an unverified body state.

Diagnostics as robot awareness

Diagnostics and calibration are the foundation for future safeguards and autonomous behaviors. A robot cannot reliably decide that it is falling, blocked, or out of bounds unless its sensors and actuators have first been characterized.

The long-term relationship is:

Diagnostics → trustworthy state
Calibration  → accurate body model
Safeguards   → safe reaction
Autonomy     → higher-level behavior

For the future autonomy model, see Auto-life and robot awareness. For the user procedure, see Getting Started.